Flue Liners for Masonry Chimneys Mount Vernon NY

Building codes require that residential masonry chimneys in Mount Vernon with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit.

Local Companies

E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Willow Snow Removal
(201) 659-7266
67 Pollock Ave
Jersey City, NJ
Malatesta Paladino Inc
(718) 523-5656
13919 109th Ave
Jamaica, NY
Franklin Stucco Of Jamaica Inc
(718) 523-0099
14815 Liberty Ave
Jamaica, NY
Academic Stone Setters Inc
(718) 463-7395
2907 119th St
Flushing, NY
Begolli Brother Construction and Restoration
(516) 476-6166
134 maple avenue
westbury, NY
Ugolini Elio Mason Contractor
(201) 433-4304
213 Harrison Ave
Jersey City, NJ
Samson Stone Co Inc
(201) 656-2417
1000 Newark Ave
Jersey City, NJ
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY

Provided By:

Source: Masonry Construction
Publication date: September 1, 1989

By Nancy J. Marshall

Abstract: Building codes require that residential masonry chimneys with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit. Chimneys usually are lined or relined with one of four types of liners: clay tile, cementitious precast, cast-in-place, or metal. Some proprietary systems are combinations of these systems.CLAY TILEClay tile is the most common way of lining residential chimneys. According to ASTM C 315, Standard Specification for Clay Flue Linings, clay tiles must be made of fire clay, shale, surface clay, or a combination of these materials.CEMENTITIOUS PRECAST LINERSOne proprietary precast flue liner is made of volcanic pumice aggregates and refractory cements. The sectional liners are about 2 feet long and come in 6-, 8-, and 10-inch inner diameters. A 2-inch space between the chimney and liners is filled with a proprietary mixture of expanded clay aggregates, portland cement, and water.CASTING LINERS IN PLACE WITH INFLATABLE FORMSOne way of casting liners is to lower a long inflatable rubber form into the flue, inflate it to the proper flue size, center it in the chimney with spacers, then fill the space between the form and the chimney with a cementitious mixture.

Click here to read full article from Masonry Construction

Related Articles
- Grout Pumps Mount Vernon NY
The GHP 2000 pump handles grout or shotcrete, and is effective in grouting small ICF projects. The product is powered by a 20-hp gasoline engine and delivers 7 cu yd of grout/hr. It has a peristaltic pump, comes with built-in jack stands to stabilize the machine, and weighs 1000 lb.
- Flashing Factors Mount Vernon NY
- How Masonry Buildings Resist Earthquakes Mount Vernon NY
- Inner Corner at Base of Wall Mount Vernon NY
- Flashing at Sills Mount Vernon NY
- Improving Company Loyalty Mount Vernon NY
- Galvanized Wall Ties Mount Vernon NY
- Galvanized Wall Ties Mount Vernon NY
- High Cement Content Problems Mount Vernon NY
- Hand-Held Power Saws Mount Vernon NY