Building codes require that residential masonry chimneys in Mahopac with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit.

Local Companies

Hull Construction and Restoration
(914) 220-0111
230 Ferris Ave
White Plains, NY
L M Construction
(631) 266-2928

Kings Park, NY
Leto Construction & Development
(518) 887-5569
1275 Scotch Church Rd
Pattersonville, NY
Sam's Masonry
(914) 964-6859
414 Warburton Ave
Yonkers, NY
Brooklyn Mason Supply Co Inc
(718) 421-0900
1593 Albany Ave
Brooklyn, NY
Calvary Construction Inc
(914) 663-6600
100 Oak St
Mount Vernon, NY
Westchester Paving & Sealing Co
(914) 667-7934
7 Wallace Ave
Mount Vernon, NY
Manhattan Molds & Cast Inc
(212) 564-3998
601 W 27th St
New York, NY
Structure Tek Masonry Division
(516) 799-2300
5394 Merrick Rd
Massapequa, NY
G & L Custom Brick Work
(718) 931-8297
937 Pierce Ave
Bronx, NY

Provided By:

Source: Masonry Construction
Publication date: September 1, 1989

By Nancy J. Marshall

Abstract: Building codes require that residential masonry chimneys with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit. Chimneys usually are lined or relined with one of four types of liners: clay tile, cementitious precast, cast-in-place, or metal. Some proprietary systems are combinations of these systems.CLAY TILEClay tile is the most common way of lining residential chimneys. According to ASTM C 315, Standard Specification for Clay Flue Linings, clay tiles must be made of fire clay, shale, surface clay, or a combination of these materials.CEMENTITIOUS PRECAST LINERSOne proprietary precast flue liner is made of volcanic pumice aggregates and refractory cements. The sectional liners are about 2 feet long and come in 6-, 8-, and 10-inch inner diameters. A 2-inch space between the chimney and liners is filled with a proprietary mixture of expanded clay aggregates, portland cement, and water.CASTING LINERS IN PLACE WITH INFLATABLE FORMSOne way of casting liners is to lower a long inflatable rubber form into the flue, inflate it to the proper flue size, center it in the chimney with spacers, then fill the space between the form and the chimney with a cementitious mixture.

Click here to read full article from Masonry Construction

Related Articles
- Grout Pumps Mahopac NY
The GHP 2000 pump handles grout or shotcrete, and is effective in grouting small ICF projects. The product is powered by a 20-hp gasoline engine and delivers 7 cu yd of grout/hr. It has a peristaltic pump, comes with built-in jack stands to stabilize the machine, and weighs 1000 lb.
- Improving Company Loyalty Mahopac NY
- Flashing at Sills Mahopac NY
- Galvanized Wall Ties Mahopac NY
- Hand-Held Power Saws Mahopac NY
- High Cement Content Problems Mahopac NY
- Galvanized Wall Ties Mahopac NY
- Flashing Factors Mahopac NY
- How Masonry Buildings Resist Earthquakes Mahopac NY
- Inner Corner at Base of Wall Mahopac NY