Flashing in Siding Installations Oakland Gardens NY

A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.

Local Companies

SilverLining Interiors, Inc.
2091 Broadway, third floor
New York, NY
BARI Tile & Ceramics Inc
(718)259-7722
8024 17th Avenue
Brooklyn, NY
Reyes Jeronimo Landscaping
(516)922-2108
61 Larrabee Avenue
Oyster Bay, NY
Tony Di Stefano Landscaping Corporation
(516)627-3524
1056 Northern Boulevard
Roslyn, NY
Vincent
Cool Tech HVAC Service LLC.

718-668-2031
1614-78th,St.
Brooklyn, NY
Alure Home Improvements
1999 Hempstead Turnpike
East Meadow, NY
Bell Bay Florist
(718)428-3166
4306 Bell Boulevard
Bayside, NY
Julie Cummings Urban Gardener
(718)788-2159
311 16th Street
Brooklyn, NY
D Ragno Landscaping Corp
(914)738-0652
604 5th Ave
Pelham, NY
CSI Landscaping
(914)723-9522
Po Box 189
Scarsdale, NY
Data Provided by:
  

Provided By:

Source: REPLACEMENT CONTRACTOR Magazine
Publication date: November 1, 2005

By Carl Sperry

A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic:

Above door and window headers.

After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose. Flashing has to be intact to do its job, which is to keep water from contact with the wall. That goes for the weather barrier as well. Run the weather barrier over the flashing so that water doesn't get behind it. You want water to run over, not under, the siding.

Inside corners.

Tough and tricky, because sometimes your weather barrier gets torn trying to fit it into corners at a 90-degree angle. A simple fix for this is bending flashing in an L-shape before installing it in the corner. Then, after flashing is installed, run weather barrier over the flashing to eliminate the worry of tearing the paper and getting a leak.

Roofs and walls.

Another overlooked detail is where roofs intersect walls. Relying on step flashing alone is usually not enough.

Click here to read full article from Replacement Contractor

Related Articles
- Fan-Fold Foam Board Oakland Gardens NY
Fan-fold foam board is widely marketed as an easy fix for improving the thermal performance and water resistance of walls when re-siding. But if not applied properly, this option could lead to moisture problems, according to leading building-science experts.
- Flashing Factors Oakland Gardens NY
- Exterior Siding Products Oakland Gardens NY
- Home Siding Tips Oakland Gardens NY