Flashing at Sills West Islip NY

Sill flashing in West Islip controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

RBK NEW YORK CORP
(516) 825-3268
29 Aberdeen Street
Malverne, NY
K & T Modde M
(718) 231-4695
4228 Carpenter Ave
Bronx, NY
Cabe Management Corp
(212) 362-6797
320 W 75th St
New York, NY
The Great Neck Manhasset Community Child Care Partnership Inc
(516) 504-0150
3 Saint Pauls Pl
Great Neck, NY
Happy Cleaning Man
(718) 531-1700
2334 Ralph Ave
Brooklyn, NY
Illuminetrix, Inc
516-798-1309
87 Pennsylvania Avenue
Massapequa, NY
Illuminations
516-766-4880
251 Sunrise Highway
Rockville Centre, NY
Nova Consultants Llc
(516) 352-3233
266 Jericho Tpke
Floral Park, NY
B W Ben Marguglio Llc
(845) 265-0123
220 Fishkill Rd
Cold Spring, NY
Hempstead Town of
(516) 489-5000

Hempstead, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Home Exterior Products West Islip NY
The Distinction Doors Signature Series of fiberglass entry doors has been expanded with the Rustic Collection. The Southwestern-style doors use the manufacturer's Hydroshield Technology to protect against moisture and water damage and prevent rotting and rusting.
- Eco-Friendly Products West Islip NY
- Flashing Factors West Islip NY
- High-Efficiency Products West Islip NY
- Home Siding Tips West Islip NY
- Flashing and Sill Products West Islip NY
- Flashing in Siding Installations West Islip NY
- Inner Corner at Base of Wall West Islip NY