Flashing at Sills Syosset NY

Sill flashing in Syosset controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

RBK NEW YORK CORP
(516) 825-3268
29 Aberdeen Street
Malverne, NY
Public Power & Utility Inc
203-333-6969
3 Parklands Drive
Darien, CT
Illuminations
516-766-4880
251 Sunrise Highway
Rockville Centre, NY
United Business Services
(516) 393-5878
6800 Jericho Tpke
Syosset, NY
Performance Development Consulting
(716) 945-0746
4039 Route 219
Salamanca, NY
Illuminetrix, Inc
516-798-1309
87 Pennsylvania Avenue
Massapequa, NY
Enhanced Home
914-560-4100
163 North Main Street
Port Chester, NY
Renaissance Electric Corp
(718) 515-2853
4039 Laconia Ave
Bronx, NY
WAC Lighting
1.800.526.2588
615 South Street
Garden City, NY
Royal Consultants
(516) 921-6255
575 Underhill Blvd Ste 200
Syosset, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Syosset NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Inner Corner at Base of Wall Syosset NY
- Flashing Factors Syosset NY
- Home Exterior Products Syosset NY
- Eco-Friendly Products Syosset NY
- Flashing in Siding Installations Syosset NY
- Flashing and Sill Products Syosset NY
- Home Siding Tips Syosset NY