Flashing at Sills Riverhead NY

Sill flashing in Riverhead controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

J M Consulting Inc
(631) 591-1632
1394 Roanoke Ave
Riverhead, NY
Kids Unlimited Preschool
(607) 431-9707
6 Country Club Rd
Oneonta, NY
Prosource Management
(212) 358-8181
928 Broadway
New York, NY
North Star Enterprises
(212) 425-4740
595 Stewart Ave
Garden City, NY
Rdm Assocs
(585) 586-6530
777 Allens Creek Rd
Rochester, NY
F B C Community Services Inc
(631) 727-0592
57 Bell Ave
Riverhead, NY
Strategic Management Consulting
(212) 280-1718
760 W End Ave
New York, NY
Human Solutions Llc
(585) 586-1717
17 Barrington Hls
Pittsford, NY
Score (Counselors To America's Small Business)
(914) 948-3907
120 Bloomingdale Rd
White Plains, NY
P D's Management
(718) 778-6770
409 Lefferts Ave
Brooklyn, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Riverhead NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Inner Corner at Base of Wall Riverhead NY
- Home Exterior Products Riverhead NY
- Flashing Factors Riverhead NY
- Flashing in Siding Installations Riverhead NY
- Eco-Friendly Products Riverhead NY
- Home Siding Tips Riverhead NY
- Flashing and Sill Products Riverhead NY