Sill flashing in Pearl River controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Weiss & Biheller
(212) 979-6990
440 Nepperhan Avenue
Yonkers, NY
Enhanced Home
914-560-4100
163 North Main Street
Port Chester, NY
Rockland Business Association Inc
(845) 735-2100
1 Bluehill
Pearl River, NY
Walker Management Inc
(718) 366-9436
919 Wyckoff Ave
Flushing, NY
Morgan Anderson Consulting
(212) 741-0777
1123 Broadway
New York, NY
Himalayan Lights
(212) 877-2159
200 W. 86th Street
New York, NY
Lighting New York
845-786-LITE (5483)
4 Carol Street
West Haverstraw, NY
Renaissance Electric Corp
(718) 515-2853
4039 Laconia Ave
Bronx, NY
Rola Management
(845) 735-8396
34 W Washington Ave
Pearl River, NY
Consulting Task Force Inc
(716) 634-7013
37 N Union Rd
Buffalo, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Pearl River NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.