Sill flashing in Patchogue controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Center Island Svces Inc
(631) 475-5600
67 Sycamore St
Patchogue, NY
Bridge Business & Property Broker
(631) 758-1639
270 E Main St
Patchogue, NY
Aristo Creative Consultants Ltd
(631) 423-3600
20 Broadhollow Rd
Melville, NY
Samson Management
(914) 833-1420
520 Larchmont Acres
Larchmont, NY
People's Management Resource
(845) 568-0185
21 N Plank Rd
Newburgh, NY
Nia Solutions Corp
(631) 207-2850
475 E Main St Ste 212
Patchogue, NY
Aspa Management Corp
(631) 289-4646
239 E Main St
Patchogue, NY
Cioffi Business Management Services
(631) 207-2227
31 W Main St
Patchogue, NY
Jfd Sales Consulting Services
(718) 729-5222
1034 44th Dr
Long Island City, NY
Smithtown Business Svces
(631) 265-0100
10 Graystone Ln
Smithtown, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Patchogue NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Home Exterior Products Patchogue NY
- Home Siding Tips Patchogue NY
- Flashing and Sill Products Patchogue NY
- Eco-Friendly Products Patchogue NY
- Flashing Factors Patchogue NY
- Flashing in Siding Installations Patchogue NY
- Inner Corner at Base of Wall Patchogue NY