Sill flashing in Ogdensburg controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Corporate Center
(315) 393-3793
812 Proctor Ave
Ogdensburg, NY
Haver Analytics Inc
(212) 986-9300
60 E 42nd St Rm 3310
New York, NY
Greenberg Zoldan Inc
(212) 931-6030
330 W 38th St Rm 801
New York, NY
Austrian Trade & Consulting Group Inc
(212) 681-7974
605 Fl 3rd Ave # 24
New York, NY
Non Profit Administrative Service
(518) 348-1398
4 Chelsea Pl
Clifton Park, NY
Coleman and Associates
(315) 394-0295
7814 State Highway 68
Ogdensburg, NY
Sterne & Co Llc
(914) 332-5720
303 S Broadway
Tarrytown, NY
Carrot Capital Llc
(212) 586-2226
140 W 57th St
New York, NY
Risk Management Publshng
(212) 286-9364
655 3rd Ave
New York, NY
C L Multiservices
(718) 684-2693
912 Soundview Ave
Bronx, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Ogdensburg NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.