Sill flashing in Mount Kisco controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Enhanced Home
914-560-4100
163 North Main Street
Port Chester, NY
Laster Richard
(914) 241-4959
103 S Bedford Rd
Mount Kisco, NY
Scs Consulting Group Inc
(914) 244-8683
344 E Main St
Mount Kisco, NY
Nasi Consulting Group
(914) 332-5522
560 White Plains Rd
Tarrytown, NY
Fairview Manhatten Asso
(914) 428-2274
90 Manhattan Ave
White Plains, NY
Lighting New York
845-786-LITE (5483)
4 Carol Street
West Haverstraw, NY
Public Power & Utility Inc
203-333-6969
3 Parklands Drive
Darien, CT
Matrix Assett Advisors Inc
(914) 241-0286
185 Kisco Ave
Mount Kisco, NY
G & V Multiservice
(718) 866-0232
620 Crescent Ave
New York, NY
Dys Management
(718) 730-9210
9340 Queens Blvd
Rego Park, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Mount Kisco NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.