Flashing at Sills Kingston NY

Sill flashing in Kingston controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Capitol Electrical Contracting, Inc.
(845) 255-7088
286 McKinstry Road
Gardiner, NY
Proteus International Inc
(845) 679-2020
124 Green St
Kingston, NY
Septon Development Group Inc
(845) 338-2835
30 Broadway
Kingston, NY
Red Flower
(212) 496-6760
609 Columbus Ave
New York, NY
Solil Managmnt
(212) 355-8194
405 E 56th St
New York, NY
Mpower Electrical & Mechanical Contracting
845-331-7022
47 Cranberry Ln
Saugerties, NY
JR Electric Service Inc.
(845) 255-4088
PO Box 243
New Paltz, NY
Personal Performance Consultants
(845) 338-0636
101 Hurley Ave
Kingston, NY
Proteus International Inc
(845) 334-8838
124 Green St
Kingston, NY
Clark Rockoff & Assocs
(718) 797-9221
75 Livingston St
Brooklyn, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Kingston NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.