Flashing at Sills Horseheads NY

Sill flashing in Horseheads controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Property Management Group
(718) 398-3923
86 Halsey St
Brooklyn, NY
Cleworth C H & Assocs Inc
(516) 482-5683
80 Nassau Dr
Great Neck, NY
Shields Associates
(212) 320-3500
140 Broadway
New York, NY
Bautista Multi Service Corp
(718) 992-4737
502 E 183rd St
Bronx, NY
Material Control Inc
(716) 759-0618
4950 Pineledge Dr E
Clarence, NY
Soaring Oaks Consulting Inc
(607) 795-9797
459 Belwood Dr
Horseheads, NY
Moderation Management Network Inc
(212) 871-0974
22 W 27th St
New York, NY
Sigma Risk Management
(516) 216-5384

Garden City, NY
D H S & Co Inc
(914) 631-2428
55 S Broadway
Tarrytown, NY
Cody Management Svcs Inc
(518) 745-7159
357 Bay Rd Ste 4
Queensbury, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Horseheads NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Home Siding Tips Horseheads NY
- Flashing in Siding Installations Horseheads NY
- Inner Corner at Base of Wall Horseheads NY
- Home Exterior Products Horseheads NY
- Flashing and Sill Products Horseheads NY
- Eco-Friendly Products Horseheads NY
- Flashing Factors Horseheads NY