Flashing at Sills Endicott NY

Sill flashing in Endicott controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Outsource Enterprises Ltd
(631) 420-4171
425 Broadhollow Rd Ste 304
Melville, NY
50 West Management Corp
(212) 245-0387
142 W 57th St
New York, NY
Ram Marketing Inc
(631) 863-2609
330 E Main St
Smithtown, NY
Baskir Capital Mgmnt Llc
(212) 664-7971
80 Columbus Cir
New York, NY
First Place Staffing
(914) 921-2015
95 Parkway Dr
Rye, NY
Universal Accounting Systems
(718) 891-8900
328 Neptune Ave
Brooklyn, NY
Spectrum Consulting Group Inc
(718) 276-7123
17040 130th Ave Apt 8D
Jamaica, NY
Jgl Management Services
(315) 255-3074
163 North St
Auburn, NY
Business-Opportunity-Offices Ltd
(845) 473-6146
42 Catharine St
Poughkeepsie, NY
Ferrier Dennis
(718) 259-6377
1724 86th St
Brooklyn, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Endicott NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.