Flashing at Sills Elmira NY

Sill flashing in Elmira controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Sixty-Two W 47 Co
(212) 719-4399
62 W 47th St
New York, NY
Cap Rio Management
(212) 697-9200
52 Vanderbilt Ave
New York, NY
Upstate Business Consultants
(315) 472-6373
500 S Salina St
Syracuse, NY
Ec Management
(631) 952-5353
60 Oser Ave
Hauppauge, NY
Workability Inc
(914) 764-0250
87 Old Mill River Rd
Pound Ridge, NY
Johnson Robert E Consulting Inc
(607) 734-4677
888 Upland Dr
Elmira, NY
Canadian Consulate General
(212) 596-1628

New York, NY
C Pf Co
(518) 786-6266
1001 Loudon Rd
Latham, NY
Health Resources Optimization Inc
(516) 616-0200
1981 Marcus Ave
New Hyde Park, NY
Zovistoski F Michael CPA
(518) 449-3166
66 State St
Albany, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Elmira NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Inner Corner at Base of Wall Elmira NY
- Home Exterior Products Elmira NY
- Flashing Factors Elmira NY
- Flashing in Siding Installations Elmira NY
- Flashing and Sill Products Elmira NY
- Home Siding Tips Elmira NY
- Eco-Friendly Products Elmira NY