Flashing at Sills Deer Park NY

Sill flashing in Deer Park controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

RBK NEW YORK CORP
(516) 825-3268
29 Aberdeen Street
Malverne, NY
WAC Lighting
1.800.526.2588
615 South Street
Garden City, NY
Research Management
(631) 595-2073
40 Burt Dr
Deer Park, NY
S H Management Group
(212) 387-9943
380 2nd Ave
New York, NY
Ksmd Caribbean Consultant Services
(718) 468-8100
19012 99th Ave
Hollis, NY
Illuminetrix, Inc
516-798-1309
87 Pennsylvania Avenue
Massapequa, NY
Illuminations
516-766-4880
251 Sunrise Highway
Rockville Centre, NY
61 East Industry Court Mngmt Co
(631) 586-8332
61 E Industry Ct
Deer Park, NY
International Management Technologies Inc
(212) 488-9400
4549 Delafield Ave
Bronx, NY
Couch Nobelius
(212) 533-9105
740 Broadway
New York, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Deer Park NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Home Exterior Products Deer Park NY
- Home Siding Tips Deer Park NY
- Eco-Friendly Products Deer Park NY
- Flashing Factors Deer Park NY
- Flashing in Siding Installations Deer Park NY
- Flashing and Sill Products Deer Park NY
- Inner Corner at Base of Wall Deer Park NY