Flashing at Sills Cohoes NY

Sill flashing in Cohoes controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Rba
(914) 762-2012
500 Executive Blvd Ste 104
Ossining, NY
Q & A Services
(718) 782-8802
672 Grand St
Brooklyn, NY
Property Management Group
(718) 398-3923
86 Halsey St
Brooklyn, NY
Cleworth C H & Assocs Inc
(516) 482-5683
80 Nassau Dr
Great Neck, NY
Shields Associates
(212) 320-3500
140 Broadway
New York, NY
Hopkins Consulting
(646) 429-1299
36 W 20th St
New York, NY
N Y State of
(212) 410-7707
413 E 120th St
New York, NY
Galileo Weather Risk Mgmt
(212) 382-1482
120 W 45th St Ste 1902
New York, NY
Moderation Management Network Inc
(212) 871-0974
22 W 27th St
New York, NY
Sigma Risk Management
(516) 216-5384

Garden City, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Eco-Friendly Products Cohoes NY
The advent of photovoltaic solar electric systems that connect and interact with grid power has opened up new categories of products to monitor, distribute, store, and control electrical supply and demand to and from solar-powered homes.