Flashing at Sills Camillus NY

Sill flashing in Camillus controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Nick Morante Consultants
(631) 285-6803
233 Union Ave
Holbrook, NY
Momar Management Corp
(516) 365-1178
44 Maple Pl
Manhasset, NY
Foote Howard S CPA
(518) 449-3166
66 State St
Albany, NY
First Option Equities
(718) 756-3351
238 Remsen Ave
Brooklyn, NY
St Management Commissary
(212) 290-8189
350 W 38th St
New York, NY
St Germain Aupperle Consltng
(315) 487-1742
6000 W Genesee St
Camillus, NY
Jubilee Homes Bus Resource Ctr
(315) 471-2720
506 W Onondaga St
Syracuse, NY
United Government Svcs
(914) 696-1233
4 W Red Oak Ln
West Harrison, NY
Bolla Management Corp
(718) 758-0900
1412 E 31st St
Brooklyn, NY
Dorino Inc
(631) 367-1156
55 W Hills Rd
Huntington Station, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Camillus NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.