Sill flashing in Bellmore controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

RBK NEW YORK CORP
(516) 825-3268
29 Aberdeen Street
Malverne, NY
WAC Lighting
1.800.526.2588
615 South Street
Garden City, NY
Property Management Group
(718) 398-3923
86 Halsey St
Brooklyn, NY
Cleworth C H & Assocs Inc
(516) 482-5683
80 Nassau Dr
Great Neck, NY
Shields Associates
(212) 320-3500
140 Broadway
New York, NY
Illuminetrix, Inc
516-798-1309
87 Pennsylvania Avenue
Massapequa, NY
Illuminations
516-766-4880
251 Sunrise Highway
Rockville Centre, NY
South Shore Adjustment Co
(516) 826-1802
2650 Merrick Rd
Bellmore, NY
Moderation Management Network Inc
(212) 871-0974
22 W 27th St
New York, NY
Sigma Risk Management
(516) 216-5384

Garden City, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Bellmore NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Eco-Friendly Products Bellmore NY
- Home Exterior Products Bellmore NY
- Home Siding Tips Bellmore NY
- Inner Corner at Base of Wall Bellmore NY
- High-Efficiency Products Bellmore NY
- Flashing in Siding Installations Bellmore NY
- Flashing Factors Bellmore NY