Flashing at Sills Baldwin NY

Sill flashing in Baldwin controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.

Local Companies

Illuminetrix, Inc
516-798-1309
87 Pennsylvania Avenue
Massapequa, NY
Illuminations
516-766-4880
251 Sunrise Highway
Rockville Centre, NY
Support A Vision
(516) 868-4673

Baldwin, NY
C D C Management
(718) 861-2916
887 Bryant Ave
Bronx, NY
Shinda Management Corp
(718) 221-5464
77 New York Ave
Brooklyn, NY
Solar Energy Systems, Inc.
(718) 389-1545
1205 Manhattan Avenue
New York, NY
RBK NEW YORK CORP
(516) 825-3268
29 Aberdeen Street
Malverne, NY
WAC Lighting
1.800.526.2588
615 South Street
Garden City, NY
Solil Managmnt
(212) 355-8194
405 E 56th St
New York, NY
F S S Group Llc
(315) 724-8244
258 Genesee St Ste 308
Utica, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 2000

Why do people install flashings beneath masonry sills? Are they required if a single-piece stone sill is used?

Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill. These flashings are especially important when using rowlock brick sills or other sills that have many joints. Multiple joints increase the risk of developing excessive water penetration into the masonry below.

In hot humid climates, sill flashings may also be helpful in preventing hot humid cavity air from condensing on the underside and perimeter of the window. In this case, the sill flashings should be integrated with a cavity seal at the window head and jambs.

When using a single-piece stone or precast concrete at a window, the flashing is less important. Very little water will penetrate a single-piece stone or concrete sill. Flashings, however, are still useful in controlling water penetration at perimeter sealant joints or preventing hot humid cavity air from reaching the perimeter of the window. Where flashing is not used, the stone or precast concrete sill should project beyond the face of the masonry and contain a drip. This will prevent water penetration at the joint beneath the sill. This joint will often crack due to differential m...

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Baldwin NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Eco-Friendly Products Baldwin NY
- High-Efficiency Products Baldwin NY
- Flashing in Siding Installations Baldwin NY
- Flashing Factors Baldwin NY
- Inner Corner at Base of Wall Baldwin NY
- Home Siding Tips Baldwin NY
- Home Exterior Products Baldwin NY