Flashing Factors Woodhaven NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Woodhaven.

Local Companies

Arcs Construction Service
(212) 722-2110
309 E 103rd St
New York, NY
UNITED CRANE RIGGING DEMOLITION
718-726-6111 973-384-5904
11-14 35TH AVENUE
LIC, NY
N & M Demolition Inc
(718) 965-8024
992 4th Avenue
Brooklyn, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
CEKInt.
(917) 477-8175---(917) 657-1389
600 West 115 Street
NYC, NY
Gorilla Contracting
516-945-7850
27 wood avenue
massapequa, NY
junk junkies, junk removal, nyc-stay clutter free, live green!
888-433-4133
229-19 merrick blvd suite345
jamaica, NY
Bolero Construction
(201) 795-3312
2780 John F Kennedy Blvd
Jersey City, NJ
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Woodhaven NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Home Exterior Products Woodhaven NY
- High-Efficiency Products Woodhaven NY
- Inner Corner at Base of Wall Woodhaven NY
- Flashing at Sills Woodhaven NY
- Eco-Friendly Products Woodhaven NY
- Green Products - Product Reviews Woodhaven NY
- Home Siding Tips Woodhaven NY
- Flashing in Siding Installations Woodhaven NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details