Flashing Factors Spencerport NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Spencerport.

Local Companies

Sheds Shacks And Shelter
585-590-9329
7003 Britt RD.
Le Roy, NY
LM Sanderson Construction Inc.
585 370 6076
891 Dewitt rd.
Webster, NY
Abr Masonry Inc
(585) 352-4430
186 Ogden Center Rd
Spencerport, NY
Atlantic Masonry Inc
(516) 798-4565

Massapequa, NY
Hopkins & Reilly Mason Contractors Inc
(315) 474-0161
419 Hiawatha Blvd
East Syracuse, NY
Professional Finishes
585-533-9140
28 academy dr.
rochester, NY
Stone Seal
585-637-6883
4929 sweden walker road
rochester, NY
CO9 STEEL
585 301 7724
310 angelus dr
ROCHESTER, NY
Delano & Dustano Masonry Constr
(516) 624-8845
19R Summit St
Oyster Bay, NY
Zentero Masonry
(845) 225-8036
7 Ticonderoga Rd
Carmel, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Spencerport NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Flashing at Sills Spencerport NY
- Flashing in Siding Installations Spencerport NY
- Inner Corner at Base of Wall Spencerport NY
- High-Efficiency Products Spencerport NY
- Green Products - Product Reviews Spencerport NY
- Home Siding Tips Spencerport NY
- Eco-Friendly Products Spencerport NY
- Home Exterior Products Spencerport NY