Flashing Factors Roosevelt NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Roosevelt.

Local Companies

Darren Construction Services, Ltd.
516-433-9000
9 Gerhard Rd.
Plainview, NY
IDC Corporation
(718) 472-4006
11-40 Borden Ave
Long Island City, NY
junk junkies, junk removal, nyc-stay clutter free, live green!
888-433-4133
229-19 merrick blvd suite345
jamaica, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Building Structures Unlimited
888-492-1136
17 Reservoir Road Suite 3A
Melville, NY
x builders inc
347-952-1776
9031 171st st 2nd floor
jamaica, NY
Personal-Touch Home Care Inc.
(718) 468-2500
186-18 Hillside Avenue
Jamaica, NY
Pinquist Tool & Die Co.,Inc
718-389-3900
63 Meserole Ave
Brooklyn, NY
Acrhitectural Metal & Glass Estimating Services LLC.
516-662-2875
96 Cypress Street
Floral Park, NY
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Roosevelt NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- High-Efficiency Products Roosevelt NY
- Eco-Friendly Products Roosevelt NY
- Inner Corner at Base of Wall Roosevelt NY
- Home Siding Tips Roosevelt NY
- Home Exterior Products Roosevelt NY
- Green Products - Product Reviews Roosevelt NY
- Flashing at Sills Roosevelt NY
- Flashing in Siding Installations Roosevelt NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details