Flashing Factors Rochester NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Rochester.

Local Companies

Professional Finishes
585-533-9140
28 academy dr.
rochester, NY
LM Sanderson Construction Inc.
585 370 6076
891 Dewitt rd.
Webster, NY
Stonelove Masonry
(585) 256-1800
1080 South Ave
Rochester, NY
International Building Blocks
(585) 544-5663
169 Newcomb St
Rochester, NY
Silveri Thos J
(585) 288-4397
32 Woodland Park
Rochester, NY
DJM Equipment
585-223-4056
7216 Palmyra Road
Fairport, NY
Stone Seal
585-637-6883
4929 sweden walker road
rochester, NY
CO9 STEEL
585 301 7724
310 angelus dr
ROCHESTER, NY
G D & V Construction Co
(585) 381-9321
365 N Washington St
Rochester, NY
Vandenberg P & Son
(585) 288-7837
89 Merchants Rd
Rochester, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall Rochester NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.