Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Port Chester.

Local Companies

Access Nursing Services
(914) 747-9696
411 Manville Road
Pleasanville, NY
Stephen C. Gidley, Inc.
(203) 655-7018
693 Post Road
Darien, CT
AM Shield Waterpoofing
516 294-8400
33 Albertson Ave.
Albertson, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Siller Stairs
(347) 491-3833
18-12 130th Street
New York, NY
A C Flooring NY Inc
914-231-6647
188 voss ave.
yonkers, NY
Walsh & Sons Blasting, Inc.
203-846-8429
119 Chestnut Hill Road
Norwalk, CT
Saugatuck Construction Group
(203) 323-6500
54 Research Drive
Stamford, CT
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Don's Doors
201-836-1598
PO Box 2140
Teaneck, NJ
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing at Sills Port Chester NY
Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.
- Flashing in Siding Installations Port Chester NY
- Home Exterior Products Port Chester NY
- Inner Corner at Base of Wall Port Chester NY
- Home Siding Tips Port Chester NY
- Eco-Friendly Products Port Chester NY
- Green Products - Product Reviews Port Chester NY
- High-Efficiency Products Port Chester NY
- Flashing and Sill Products Port Chester NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details