Flashing Factors Pearl River NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Pearl River.

Local Companies

Cross Coungy Woodworking
914-447-4671
20 Gunther Ave
Yonkers, NY
Pantheon Industries
(212) 828-1823
1500 Lexington Avenue
New York, NY
Custom Crushing & Materials, Inc.
914.737.6400
522 N. State Rd.
Briarcliff Manor, NY
New York State Construction
(845) 641-3382
7 Skyline Dr
Thiells, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Bac Construction
(212) 348-1758
3 E 94th St
New York, NY
James Kurpiel Iinc
201-342-3170
19 orchard street
hackensack, NJ
fabian nova
(914) 843-2838
32 maple av
mt kisco, NY
JBS WATERPROOFING & ROOFING
(347) 583-5313
1149 white plains rd
bronx, NY
Double Deckers
(845) 356-3325
6 Melnick Dr
Monsey, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Pearl River NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Home Siding Tips Pearl River NY
- Home Exterior Products Pearl River NY
- High-Efficiency Products Pearl River NY
- Flashing at Sills Pearl River NY
- Green Products - Product Reviews Pearl River NY
- Eco-Friendly Products Pearl River NY
- Flashing in Siding Installations Pearl River NY
- Inner Corner at Base of Wall Pearl River NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details