Flashing Factors Ossining NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Ossining.

Local Companies

A C Flooring NY Inc
914-231-6647
188 voss ave.
yonkers, NY
LL Construction Enterprises, Inc.
914-447-8246
211 Ashburton Ave
Yonkers, NY
GLOBAL CONSTRUCTION
914 406 5513
838 MCLEAN AVE
YONKERS, NY
New York State Construction
(845) 641-3382
7 Skyline Dr
Thiells, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
McFarlane Brothers Asphalt Paving
201-327-5258
120 East Main St. Suite 337
Ramsey, NJ
Mr. Handyman
914-461-3400
719 West Nyack Rd
West Nyack, NY
Dennis Forte Construction, LLC
914-202-8720
53 Lispenard Ave.
Bronxville, NY
TDEV Construction Services Inc
203-406-0201
0 Halloween Blvd
Stamford, CT
Double Deckers
(845) 356-3325
6 Melnick Dr
Monsey, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Ossining NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Flashing and Sill Products Ossining NY
- Inner Corner at Base of Wall Ossining NY
- Home Siding Tips Ossining NY
- Flashing at Sills Ossining NY
- Green Products - Product Reviews Ossining NY
- Eco-Friendly Products Ossining NY
- Home Exterior Products Ossining NY
- High-Efficiency Products Ossining NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details