Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Orchard Park.

Local Companies

Harry R. Defler Corp.
(716) 839-3727
4446 Main St.
Buffalo, NY
Lori Desormeau
(716) 863-6689
112 Norwood Ave.
Buffalo, NY
Electrolab, Inc.
(716) 833-4457
4535 Bailey Ave.
Buffalo, NY
Warehouse Wholesaler.com
(716) 947-5552
3774 Lake Shore Rd.
Buffalo, NY
Nussbaumer & Clarke, Inc.
(716) 827-8000
3556 Lake Shore Rd., Ste. 500
Buffalo, NY
Schneider Design Architects, P.C.
(716) 923-7000
443 Delaware Ave., Ste. 200
Buffalo, NY
Imperial Concrete Co., Inc.
(716) 867-5696
17 Santa Clara Ct.
East Amherst, NY
Patrick N. Marsillo Home Repairs
(716) 649-0382
4909 Bayview Rd.
Hamburg, NY
RMS Material Handling
(716) 689-8425
151 Presidents Walk
Buffalo, NY
MJ Mechanical Services, Inc.
(716) 874-9200
2040 Military Rd.
Tonawanda, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Orchard Park NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Home Siding Tips Orchard Park NY
- Eco-Friendly Products Orchard Park NY
- Flashing in Siding Installations Orchard Park NY
- Flashing and Sill Products Orchard Park NY
- Flashing at Sills Orchard Park NY
- Home Exterior Products Orchard Park NY
- Inner Corner at Base of Wall Orchard Park NY
- Green Products - Product Reviews Orchard Park NY