Flashing Factors Niagara Falls NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Niagara Falls.

Local Companies

Gordon W. Jones Associates
(716) 633-9000
5757 Main St.
Williamsville, NY
Turner Construction Co.
(716) 853-1900
135 Delaware Ave., Ste. 407
Buffalo, NY
Huber Electric, Inc
(716) 824-8816
231 Chamberlin Dr.
Buffalo, NY
Goergen-Mackwirth Co., Inc.
(716) 874-4800
765 Hertel Ave.
Buffalo, NY
Rkp-Partex International
(716) 565-1900
430 Lawrence Bell Dr., Ste. 11
Buffalo, NY
Niagara Gutter Inc.
716-695-3500
1503 Forest Edge Dr.
East Amherst, NY
John Wingfelder Architect
(716) 833-5009
272 Huntington Ave.
Buffalo, NY
Design For Industry, Inc.
(716) 204-0299
425 Cayuga Rd., Ste. 400
Cheektowaga, NY
Tolar Manufacturing Co., Inc.
(716) 688-4906
7954 Transit Rd., Ste. 315
Williamsville, NY
Husky Injection Molding Systems, Inc.
(716) 630-7300
55 Amherst Villa Rd.
Buffalo, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Niagara Falls NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Flashing and Sill Products Niagara Falls NY
- Home Exterior Products Niagara Falls NY
- High-Efficiency Products Niagara Falls NY
- Home Siding Tips Niagara Falls NY
- Inner Corner at Base of Wall Niagara Falls NY
- Flashing at Sills Niagara Falls NY
- Green Products - Product Reviews Niagara Falls NY
- Eco-Friendly Products Niagara Falls NY