Flashing Factors New York NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in New York.

Local Companies

Alpha Construction Group Inc
(212) 868-5515
115 W 29th St
New York, NY
new age roofing
718-626-0027
60-74 70 street
maspeth, NY
Studio 22 Architecture PC
(212) 988-1067
191 E. 76th Street
New York, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Olim Construction Inc.
646-294-5077
8510 34th Ave Apt.420
Jackson Heights, NY
170 East End Ave Construction Llc
(212) 288-1114
534 E 88th St
New York, NY
Elmont glass
516 248 8860
2145 jericho tpke
Garden city park, NY
N & M Demolition Inc
(718) 965-8024
992 4th Avenue
Brooklyn, NY
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations New York NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Home Exterior Products New York NY
- Inner Corner at Base of Wall New York NY
- Green Products - Product Reviews New York NY
- Home Siding Tips New York NY
- Flashing at Sills New York NY
- Flashing and Sill Products New York NY
- High-Efficiency Products New York NY
- Eco-Friendly Products New York NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details