Flashing Factors New City NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in New City.

Local Companies

JF CONSTRUCTION
973-930-7751
251 PACIFI CST
PATERSON, NJ
Mr. Handyman
914-461-3400
719 West Nyack Rd
West Nyack, NY
fabian nova
(914) 843-2838
32 maple av
mt kisco, NY
Going Green Home Decor
201.488.8889
180 Main ST
Hackensack, NJ
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
CLODEM CONSTRUCTION
914 803-7177
1-5TH STREET SUIT #3
NEW ROCHELLE, NY
Cross Coungy Woodworking
914-447-4671
20 Gunther Ave
Yonkers, NY
MCFARLANE PAVING
201-327-1591
23 BRIARCLIFF RD
UPPERSADDLE RIVER, NJ
Custom Crushing & Materials, Inc.
914.737.6400
522 N. State Rd.
Briarcliff Manor, NY
Double Deckers
(845) 356-3325
6 Melnick Dr
Monsey, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall New City NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Home Siding Tips New City NY
- Home Exterior Products New City NY
- Flashing in Siding Installations New City NY
- Eco-Friendly Products New City NY
- Flashing at Sills New City NY
- High-Efficiency Products New City NY
- Green Products - Product Reviews New City NY
- Flashing and Sill Products New City NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details