Flashing Factors Monsey NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Monsey.

Local Companies

N&S GENERALCONTRACTOR
(973) 725-4058
23 10th ave
Hawthorne, NJ
fagundez painting inc
305 742 9220-973 341 6391
556 market st
paterson, NJ
Mr. Handyman
914-461-3400
719 West Nyack Rd
West Nyack, NY
Custom Crushing & Materials, Inc.
914.737.6400
522 N. State Rd.
Briarcliff Manor, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Cross Coungy Woodworking
914-447-4671
20 Gunther Ave
Yonkers, NY
McFarlane Aspalt
201-327-5258
120 E Main St
Ramsey, NJ
ONLINE SEAMLESS GUTTER
973 997 03 41
53 BARKLEY AVE
CLIFTON, NJ
MCFARLANE PAVING
201-327-1591
23 BRIARCLIFF RD
UPPERSADDLE RIVER, NJ
GLOBAL CONSTRUCTION
914 406 5513
838 MCLEAN AVE
YONKERS, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Monsey NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Inner Corner at Base of Wall Monsey NY
- Home Siding Tips Monsey NY
- Eco-Friendly Products Monsey NY
- Home Exterior Products Monsey NY
- High-Efficiency Products Monsey NY
- Flashing at Sills Monsey NY
- Green Products - Product Reviews Monsey NY
- Flashing in Siding Installations Monsey NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details