Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Mineola.

Local Companies

B & B Construction
(212) 661-6008
420 Lexington Ave
New York, NY
Transammonia Inc.
(212) 223-3200
320 Park Avenue
New York, NY
GREAT AMERICAN COLORS LLC - CONTRACTORS
(201) 440-0505
730 GRAND AVE
RIDGEFIELD, NJ
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Above Remodeling Corporation
(212) 939-7571
295 Madison Avenue
New York, NY
CEKInt.
(917) 477-8175---(917) 657-1389
600 West 115 Street
NYC, NY
170 East End Ave Construction Llc
(212) 288-1114
534 E 88th St
New York, NY
NY Construction & Stone Inc.
718 204-6100
2145, 23 Street
Astoria, NY
JBS WATERPROOFING & ROOFING
(347) 583-5313
1149 white plains rd
bronx, NY
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing at Sills Mineola NY
Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.
- Home Exterior Products Mineola NY
- High-Efficiency Products Mineola NY
- Flashing in Siding Installations Mineola NY
- Eco-Friendly Products Mineola NY
- Flashing and Sill Products Mineola NY
- Green Products - Product Reviews Mineola NY
- Inner Corner at Base of Wall Mineola NY
- Home Siding Tips Mineola NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details