Flashing Factors Mahopac NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Mahopac.

Local Companies

GMR
(203) 942-6756
8LAKE AVE AP3 DANBURY CT
DANBURY, CT
Cafarelli Carpentry, Tile and Handyman Contracting
845-453-1690
33 Townview Dr
Wappingers falls, NY
N E C NORTH EASTERN CONTRACTING
845-298-4400
1127 RT 9
wappinger falls, NY
hk contracting inc.
914 473 2355
po box 529
scrub oak, NY
A. Prokosch & Sons/Pro-Air Heating & Air Conditioning
845-913-7191
772 South Street
Newburgh, NY
NORTH EASTERN CONTRACTING
914-490-4100
1127 rt.9
wappinger falls, NY
Pioneer Blacktopping
(123) 456-7890
10 North Street
Wappingers Falls, NY
fabian nova
(914) 843-2838
32 maple av
mt kisco, NY
Custom Crushing & Materials, Inc.
914.737.6400
522 N. State Rd.
Briarcliff Manor, NY
mv custom inc mvcustominc.com
845 226-2375
803 beekman road
hopewell jct, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Mahopac NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Home Exterior Products Mahopac NY
- Flashing at Sills Mahopac NY
- Eco-Friendly Products Mahopac NY
- Green Products - Product Reviews Mahopac NY
- Inner Corner at Base of Wall Mahopac NY
- Flashing and Sill Products Mahopac NY
- High-Efficiency Products Mahopac NY
- Home Siding Tips Mahopac NY