Flashing Factors Lockport NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Lockport.

Local Companies

Achieve Architecture, LLP
(716) 626-6719
59 Chaumont Dr.
Williamsville, NY
U*C Coatings Corporation
(716) 833-9366
2250 Fillmore Ave.
Buffalo, NY
Robert Miller Construction, Inc.
(716) 434-8807
PO Box 480
Lockport, NY
Federal Building Co., Inc.
(716) 885-5400
298 Ashland Ave.
Buffalo, NY
Klein Steel Service, Inc.
(716) 826-6060
1050 Military Rd.
Buffalo, NY
R.B. U'Ren Equipment, Inc.
1-800-330-UREN
1120 Connecting Road
Niagara Falls, NY
Cannon Design
(716) 773-6800
2170 Whitehaven Rd.
Grand Island, NY
Cameron Compression Systems
(716) 891-3895
3101 Broadway
Buffalo, NY
MVK International Corp.
(716) 895-8569
152 Halston Pkwy.
East Amherst, NY
Holiday Lumber Co.
(716) 863-6338
22 Sussex Ln.
Lancaster, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall Lockport NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Home Siding Tips Lockport NY
- Flashing and Sill Products Lockport NY
- Eco-Friendly Products Lockport NY
- Flashing in Siding Installations Lockport NY
- Flashing at Sills Lockport NY
- Green Products - Product Reviews Lockport NY
- High-Efficiency Products Lockport NY
- Home Exterior Products Lockport NY