Flashing Factors Lancaster NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Lancaster.

Local Companies

Glauber Equipment Corp.
(716) 681-1234
1600 Commerce Pkwy.
Lancaster, NY
Barbalato Builders, Inc.
(716) 689-2409
315 West Klein Rd.
Williamsville, NY
MVK International Corp.
(716) 895-8569
152 Halston Pkwy.
East Amherst, NY
Jackye Mandell Interiors
(716) 833-6477
78 Starin Ave.
Buffalo, NY
Buffalo Crushed Stone, Inc.
(716) 826-7310
2544 Clinton St.
Buffalo, NY
A+ Contractors of WNY
716-568-4198
3840 E. Robinson Rd. #226
Amherst, NY
Frey Electric Construction Co., Inc.
(716) 874-1710
100 Pearce Ave.
Tonawanda, NY
Robert Miller Construction, Inc.
(716) 434-8807
PO Box 480
Lockport, NY
Marrano/Marc-Equity Corp.
(716) 675-1200
2730 Transit Rd.
West Seneca, NY
Ace Paving Co., Inc.
(716) 683-1333
8 Birchwood Common
Lancaster, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Lancaster NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Green Products - Product Reviews Lancaster NY
- Inner Corner at Base of Wall Lancaster NY
- High-Efficiency Products Lancaster NY
- Home Exterior Products Lancaster NY
- Flashing at Sills Lancaster NY
- Flashing in Siding Installations Lancaster NY
- Home Siding Tips Lancaster NY
- Eco-Friendly Products Lancaster NY