Flashing Factors Howard Beach NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Howard Beach.

Local Companies

MSA QUALITY,INC
(347) 499-1141
2800 COYLE
brooklyn, NY
Bargain Tile
516-593-3939
430 Sunrise Highway
Lynbrook, NY
Costanza Iron Works LLC
718 345 5500
49 Hinsdale Street
Brooklyn, NY
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Topnotch construction & landscaping service inc
(646) 533-2645
17711 145TH RD
Jamaica, NY
Arcon Construction Services
(212) 752-3261
411 E 57th St
New York, NY
ContiGroup
(212) 207-5100
277 Park Avenue
New York, NY
CWC Plumbing and Heating LLC
718-268-8898
90-04A 70th Avenue
Forest Hills, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall Howard Beach NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Eco-Friendly Products Howard Beach NY
- Home Siding Tips Howard Beach NY
- Home Exterior Products Howard Beach NY
- Flashing in Siding Installations Howard Beach NY
- High-Efficiency Products Howard Beach NY
- Flashing and Sill Products Howard Beach NY
- Flashing at Sills Howard Beach NY
- Green Products - Product Reviews Howard Beach NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details