Flashing Factors Hopewell Junction NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Hopewell Junction.

Local Companies

ilias painting and paper hanging inc
845-282-9066
53 rodeo dr
hopewell jct, NY
mv custom inc mvcustominc.com
845 226-2375
803 beekman road
hopewell jct, NY
Marquette Building & Consultation Svcs.
(845) 255-8560
149 Forest Glen Road
New Paltz, NY
David Clouser & Associates
(845) 256-9600
1 Paradies Lane, Suite 200
New Paltz, NY
Mc Auliffe Construction Co
845-225-1746 or 914-419-7101
Po Box 810 Carmel, NY.
Carmel, NY
Pioneer Blacktopping
(123) 456-7890
10 North Street
Wappingers Falls, NY
N E C NORTH EASTERN CONTRACTING
845-298-4400
1127 RT 9
wappinger falls, NY
Cooper & Company
(914) 456-9900
PO Box 344
West Park, NY
Erdman Anthony & Associates, Inc.
(845) 883-5078
60 Park Lane, Suite 1
Highland, NY
Living Art Landscapes Inc.
(845) 691-8992
428 N. Riverside Rd
Highland, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Hopewell Junction NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Home Exterior Products Hopewell Junction NY
- Flashing and Sill Products Hopewell Junction NY
- Green Products - Product Reviews Hopewell Junction NY
- High-Efficiency Products Hopewell Junction NY
- Home Siding Tips Hopewell Junction NY
- Eco-Friendly Products Hopewell Junction NY
- Inner Corner at Base of Wall Hopewell Junction NY
- Flashing at Sills Hopewell Junction NY