Flashing Factors Farmingville NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Farmingville.

Local Companies

all stone restoration
631 780 5404
po box 115
smithtown ny, NY
Good Earth Sales
516-818-2746
po box 711
medford, NY
Amato Masonry
(631) 451-7047
627 Horseblock Rd
Farmingville, NY
Sam's Masonry Corp
(631) 451-0622
14 Hickory Ave
Farmingville, NY
Truckloaders
631-872-2275
West Jericho Tpk
Smithtown, NY
Autumn Masonry
631-828-1687
10 Locust Avenue
Coram, NY
Building Structures Unlimited
888-492-1136
17 Reservoir Road Suite 3A
Melville, NY
Silnap Corp
(631) 451-6076
627 Horseblock Rd Ste 6
Farmingville, NY
Jc Concrete Inc
(631) 736-9528
72 Abner Dr
Farmingville, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Farmingville NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Home Siding Tips Farmingville NY
- Home Exterior Products Farmingville NY
- Flashing and Sill Products Farmingville NY
- Flashing at Sills Farmingville NY
- High-Efficiency Products Farmingville NY
- Eco-Friendly Products Farmingville NY
- Inner Corner at Base of Wall Farmingville NY
- Green Products - Product Reviews Farmingville NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details