Flashing Factors Elmhurst NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Elmhurst.

Local Companies

American Construction Corp
(212) 229-5200
44 W 18th St
New York, NY
GLOBAL CONSTRUCTION
914 406 5513
838 MCLEAN AVE
YONKERS, NY
Bolero Construction
(201) 795-3312
2780 John F Kennedy Blvd
Jersey City, NJ
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Haroon Contracting Inc
(646) 667-5381
1578 williamsbridge road
bronx, NY
Alex Manuele Stairbuilder
(212) 233-9159
67 Murray St
New York, NY
Automated Shading
212 929 9206
917 74th St
North Bergen, NJ
KNK Construction Inc
212 398-1014
155 Avenue of the Americas 3rd Fl
New York, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Elmhurst NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Home Exterior Products Elmhurst NY
- Eco-Friendly Products Elmhurst NY
- High-Efficiency Products Elmhurst NY
- Flashing and Sill Products Elmhurst NY
- Home Siding Tips Elmhurst NY
- Flashing at Sills Elmhurst NY
- Green Products - Product Reviews Elmhurst NY
- Inner Corner at Base of Wall Elmhurst NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details