Flashing Factors East Syracuse NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in East Syracuse.

Local Companies

J.P. Megnin General Contracting
(315)391-1383
938 Cty Rt 11
West Monroe, NY
Ryan Heneka's Decorative Concrete
315.506.0336
105 Melvin Avenue
Liverpool, NY
New Heritage Woodworking
315-677-3884
7022 Bush Road
Jamesville, NY
Hess Corporation
(315) 234-5330
100 Clinton Sq.
Syracuse, NY
Nu-Crete
315-720-6599
P.O. Box 145
Baldwinsville, NY
Distinctive Innovations, Inc.
315-696-6672
9 Clinton St.
Tully, NY
Expert Chimney Services, Inc
315 469 5004
4800 McDonald Rd
Syracuse, NY
Oneida Valley Abstract Corp.
(315) 363-1444
PO box 296
Wampsville, NY
Hopkins & Reilly Mason Contractors Inc
(315) 474-0161
419 Hiawatha Blvd
East Syracuse, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall East Syracuse NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Eco-Friendly Products East Syracuse NY
- Home Exterior Products East Syracuse NY
- Green Products - Product Reviews East Syracuse NY
- Home Siding Tips East Syracuse NY
- Flashing at Sills East Syracuse NY
- Flashing and Sill Products East Syracuse NY
- Flashing in Siding Installations East Syracuse NY
- High-Efficiency Products East Syracuse NY