Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in East Aurora.

Local Companies

Gordon W. Jones Associates
(716) 633-9000
5757 Main St.
Williamsville, NY
The Revvo Caster Company, Inc.
(716) 675-9609
2420 North America Dr.
West Seneca, NY
Imperial Concrete Co., Inc.
(716) 867-5696
17 Santa Clara Ct.
East Amherst, NY
Patrick N. Marsillo Home Repairs
(716) 649-0382
4909 Bayview Rd.
Hamburg, NY
Julius Blum & Sons Builders, Inc.
(716) 741-9970
8570 Roll Rd.
Clarence Center, NY
Achieve Architecture, LLP
(716) 626-6719
59 Chaumont Dr.
Williamsville, NY
Schneider Design Architects, P.C.
(716) 923-7000
443 Delaware Ave., Ste. 200
Buffalo, NY
Tiles International
(716) 662-4441
6140 W. Quaker St.
Orchard Park, NY
Tolar Manufacturing Co., Inc.
(716) 688-4906
7954 Transit Rd., Ste. 315
Williamsville, NY
Eberl Iron Works, Inc.
(716) 854-7633
128 Sycamore St.
Buffalo, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall East Aurora NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Flashing and Sill Products East Aurora NY
- Home Exterior Products East Aurora NY
- Green Products - Product Reviews East Aurora NY
- Eco-Friendly Products East Aurora NY
- Flashing at Sills East Aurora NY
- Flashing in Siding Installations East Aurora NY
- Home Siding Tips East Aurora NY
- High-Efficiency Products East Aurora NY