Flashing Factors Corning NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Corning.

Local Companies

Albert Volz
(631) 331-3771
15 Millard Ave
Miller Place, NY
Rapid Masonry Restoration Inc
(212) 695-2170
38 W 32nd St
New York, NY
K T Constr Inc
(631) 673-1446
290 Pidgeon Hill Rd
Huntington Station, NY
Nicarro Land Development
(516) 338-2053
211 Drexel Ave
Westbury, NY
Calvary Construction Inc
(914) 663-6600
100 Oak St
Mount Vernon, NY
Cystal Valley Excavation/Mulch/Gravel
607-765-8124
20 River Road
Corning, NY
Miller Kenneth
(315) 737-8401
2857 Oneida St
Sauquoit, NY
Absolute Chimney Svce
(914) 949-1760
4 Broadway
Valhalla, NY
Abr Masonry Inc
(585) 352-4430
186 Ogden Center Rd
Spencerport, NY
Bullis Landscape
(845) 358-1142

Nyack, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing at Sills Corning NY
Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.