Flashing Factors Corning NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Corning.

Local Companies

Brookfield Maintenance
(631) 789-3955
23 Grand Ave
Farmingdale, NY
Wagner Masonry
(845) 252-7425
545 Skipperene Rd
Cochecton, NY
Genteel Home Enhancements Ltd
(585) 225-1070
2897 Ridgeway Ave
Rochester, NY
Shore General Cntrctng
(718) 720-5700
83 Woodland Dr
Middletown, NY
Verde & Son Contracting Inc
(718) 381-8800
254 Irving Ave
Brooklyn, NY
Cystal Valley Excavation/Mulch/Gravel
607-765-8124
20 River Road
Corning, NY
Wpl Masonry
(914) 949-1214
114 N Broadway
White Plains, NY
Seven Stars Construction Inc
(631) 451-1787

Medford, NY
Cruz Constr Co
(631) 728-5419
2 Emerson Ct
Hampton Bays, NY
D & L Masonry-Builders Inc
(518) 869-7134
1092 Watervliet Shaker Rd
Albany, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Corning NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Home Exterior Products Corning NY
- Green Products - Product Reviews Corning NY
- Home Siding Tips Corning NY
- Flashing at Sills Corning NY
- High-Efficiency Products Corning NY
- Flashing and Sill Products Corning NY
- Inner Corner at Base of Wall Corning NY
- Eco-Friendly Products Corning NY