Flashing Factors Commack NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Commack.

Local Companies

Great Neck Saw Manufacturers
(516) 746-5352
165 East Second Street
Mineola, NY
Autumn Masonry
631-828-1687
10 Locust Avenue
Coram, NY
Gorilla Contracting
516-945-7850
27 wood avenue
massapequa, NY
Fox Hill Builders, Inc.
(203) 655-9046
1921 Post Road
Darien, CT
Total Home Construction Corp (since 1989)
(516) 822-4747
1120 Old Country Rd
Plainview, NY
Darren Construction Services, Ltd.
516-433-9000
9 Gerhard Rd.
Plainview, NY
all stone restoration
631 780 5404
po box 115
smithtown ny, NY
Good Earth Sales
516-818-2746
po box 711
medford, NY
VISCO ASBESTOS REMOVAL
516 547 2510
235 ROBINS LA
SYOSSET, NY
Pro Qualtiy Home Improvements Inc.
631 393 6812
500 Bi-County Blvd.
Farmingdale, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing at Sills Commack NY
Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.
- High-Efficiency Products Commack NY
- Inner Corner at Base of Wall Commack NY
- Green Products - Product Reviews Commack NY
- Flashing and Sill Products Commack NY
- Home Exterior Products Commack NY