Flashing Factors Centereach NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Centereach.

Local Companies

all stone restoration
631 780 5404
po box 115
smithtown ny, NY
Good Earth Sales
516-818-2746
po box 711
medford, NY
Pro Qualtiy Home Improvements Inc.
631 393 6812
500 Bi-County Blvd.
Farmingdale, NY
Masonry Works Construction Inc
(914) 654-1843
11 Overman Pl
New Rochelle, NY
Wal-Mart Connection Center
(631) 345-3012
750 Middle Country Rd
Middle Island, NY
Truckloaders
631-872-2275
West Jericho Tpk
Smithtown, NY
Autumn Masonry
631-828-1687
10 Locust Avenue
Coram, NY
JC Homecare
631 756 5600
200 Rt 110
Farmingdale, NY
Building Structures Unlimited
888-492-1136
17 Reservoir Road Suite 3A
Melville, NY
Cypress Construction Corp
(718) 428-6905
25421 39th Ave
Little Neck, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing and Sill Products Centereach NY
We've all seen the images of mold-infested homes that headlined media and courtrooms a few years ago–or experienced it firsthand–with faulty window installation often front and center as a main point of failure.
- Green Products - Product Reviews Centereach NY
- Flashing in Siding Installations Centereach NY
- Home Siding Tips Centereach NY
- Inner Corner at Base of Wall Centereach NY
- Flashing at Sills Centereach NY
- Eco-Friendly Products Centereach NY
- High-Efficiency Products Centereach NY
- Home Exterior Products Centereach NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details