Flashing Factors Beacon NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Beacon.

Local Companies

Cafarelli Carpentry, Tile and Handyman Contracting
845-453-1690
33 Townview Dr
Wappingers falls, NY
Water Solutions of New Paltz, Inc.
(845) 255-3408
PO Box 221
New Paltz, NY
Energy Appreciators
(845) 883-0917
1914 Rt 44/55
Modena, NY
Larenco, LLC
(914) 629-0798
PO Box 1502
Highland, NY
Mc Auliffe Construction Co
845-225-1746 or 914-419-7101
Po Box 810 Carmel, NY.
Carmel, NY
Pioneer Blacktopping
(123) 456-7890
10 North Street
Wappingers Falls, NY
MV custom inc
845 2262375
803 beekman road
hopewell jct, NY
Marquette Building & Consultation Svcs.
(845) 255-8560
149 Forest Glen Road
New Paltz, NY
Jim Whitney Home Improvements
(845) 255-2773
75 Dug Rd.
New Paltz, NY
Erdman Anthony & Associates, Inc.
(845) 883-5078
60 Park Lane, Suite 1
Highland, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall Beacon NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Green Products - Product Reviews Beacon NY
- Home Siding Tips Beacon NY
- Eco-Friendly Products Beacon NY
- Flashing at Sills Beacon NY
- Flashing and Sill Products Beacon NY
- High-Efficiency Products Beacon NY
- Flashing in Siding Installations Beacon NY
- Home Exterior Products Beacon NY