Flashing Factors Astoria NY

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments in Astoria.

Local Companies

MSA QUALITY,INC
(347) 499-1141
2800 COYLE
brooklyn, NY
Gume &Sons
(914) 433-4098
103 Palisade ave
Yonkers, NY
jose painting
347-694-9691
3758 101st
corona, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Green Tree Construstion
201.300.6906
33 Broadway
Fair Lawn, NJ
Pantheon Industries
(212) 828-1823
1500 Lexington Avenue
New York, NY
JBS WATERPROOFING & ROOFING
(347) 583-5313
1149 white plains rd
bronx, NY
Miele Iron Works, Inc - Custom Cellar Doors
(908) 686-0943
2340 Route 22 East
Union, NJ
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2005

Should flashing be used beneath rowlock brick window sills? If through-wall flashing is installed beneath these rowlocks, how are the sills anchored? If the anchors penetrate the flashing, does this lead to deterioration of the masonry below in freeze-thaw environments?

Rowlock brick sills contain many joints and are particularly susceptible to water penetration. For this reason, I do not recommend their use in freeze-thaw environments.

When they are used in freeze-thaw environments, however, the flashing beneath them is critical to prevent water from saturating the top of the masonry wall below. Snow and ice collects on the rowlock sills. When they melt, water can penetrate the sills and refreeze, resulting in deterioration. This scenario is a particular problem with the anchorage of these sills because they break apart.

When rowlock sills are used, they can be anchored using galvanized corrugated wall ties in the head joint between every fourth to sixth brick unit. When possible, I prefer that these anchors be attached to the backup wall on the vertical face, behind the sill.

It also is possible to extend flat strap anchors through the flashing. However, any penetrations through the flashing must be carefully sealed.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Astoria NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Flashing at Sills Astoria NY
- Eco-Friendly Products Astoria NY
- Home Exterior Products Astoria NY
- Inner Corner at Base of Wall Astoria NY
- High-Efficiency Products Astoria NY
- Flashing and Sill Products Astoria NY
- Home Siding Tips Astoria NY
- Green Products - Product Reviews Astoria NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details