Eliminating Swirls in Precast Panels North Tonawanda NY

What can we do to eliminate swirls in precast panels? Sid Freedman of the Precast/Prestressed Concrete Institute says such swirls are signs of segregation caused by the placing method. Read on to know more.

Local Companies

RC Tonewoods
716-873-6043
1109 Military Road
Buffalo, NY
Woodcraft - Buffalo, NY
(716) 674-0795
1900 Ridge Road
West Seneca, NY
Standish-Jones Building Supply
(716) 772-2611
4440 Central Ave
Gasport, NY
Do it Best/Maple-Amherst Hardware
716-688-4488
876 Maple Road
Williamsville, NY
Kmart 7171 / Cross Merch
(716) 668-0251
1460 French Rd
Depew, NY
Advantage Trim & Lumber Co
716-827-3915
601 Ohio St
Buffalo, NY
Rockler Woodworking and Hardware #11
(716) 631-8922
5085 Transit Rd
Buffalo, NY
Spalding Ace Hardware
(716) 433-8155
215 Davison Rd
Lockport, NY
Philipps Bros. Supply
2525 Kensington Ave Amherst, NY, 14226
Amherst, NY
The Home Depot
(716)895-6680
300 Thruway Plaza Dr
Cheektowaga, NY
Data Provided by:
  

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: December 1, 1998

We produce precast exposed-aggregate sandwich panels using concrete made with Type III cement, a 0.38 water-cementitious materials ratio and enough superplasticizer to achieve a 7- to 8-inch slump. The forming bed is made of wood. Using a bucket that passes down the center of the bed, we pour enough concrete for a 3-inch-thick layer and rake the concrete to the edges. We consolidate that layer with an immersion vibrator, then screed it off before adding a 2-inch-thick insulation board and 3 more inches of concrete.When we sandblast the formed panel surface to expose the 1/2-inch limestone, the limestone particles appear in groups or swirls. What can we do to eliminate this problem?

Sid Freedman of the Precast/Prestressed Concrete Institute says such swirls are signs of segregation caused by the placing method. You should place concrete on top of concrete in successive bucket passes because blending separate puddles or passes of concrete creates areas that are heavy in mortar. Raking can cause a similar problem.Ed Boyle, plant manager at Lombard Architectural Precast, Alsip, Ill., suggests using a placing bucket with a wider-than-normal gate, then overlapping each successive pass to eliminate paste streaks.He also suggests using a vibrating screed that hangs off of the form side rails at the correct depth to consolidate your first layer of concrete.

Click here to read full article from The Concrete Producer